Solar system sizing

Nomad Life Wiki

“ I'd say 500 watts is the minimum for the [Pacific Northwest] in winter and you would be better off with [750 watts] if you can get it on the roof.[1]”

Sizing a solar system for an off-grid house is relatively easy: calculate household power needs in the worst case scenario (sustained cloudy winter days in that specific geographic area)[2] and pay for it.

Solar configurations for nomadic living have more variables:

  • worst case scenario loads (the max loads you will apply in any 24hr period, or at any given time, if you plan to run heavy loads)
  • worst case scenario sunlight, usually December in your geographical area due to shortest daylight hours, but also affected by tree canopies, mountains, "urban canyons", or other forms of shading
  • days of reserve (with no solar charging) you'll need
  • whether or not you have access to other forms of charging: shore power, alternator charging, generators
  • the kind of batteries you have - lithium, for example, charges more efficiently than lead-acid
  • the kind of camping you do. Full-timers will need more robust systems. Weekenders can "get by" then recharge batteries fully at home.

These factors will dictate the system capacity you will need. If the system you need will not physically fit on/in your vehicle, you will have to take a different approach.

The first step in (and difficult part of) designing a solar setup for your camper is to understand your real power needs. Most people running on solar power only (as when boondocking) will need to reset expectations to be more in line with reality:

  • Necessities like charging phones, LED lighting, fans, etc. are easy to power.
  • "Niceties" like electric coffee makers, toasters, hot plates, induction cooktops, and microwaves require big/costly setups.
  • Luxuries like air conditioning require very large/expensive solar systems (or cheaper shore power or generator usage)

Your daily power needs

Before you dig in, consider that it is far easier and cheaper to use less power than it is to make more power.

Power requirements are usually expressed in Amp-hours needed every day (Ah/day), although thinking in Watt-hours (Wh) might be less complicated.

There are two different kinds of electrical loads nomads usually run, AC (alternating current, usually 110v or 220v) and DC (direct current, usually 12v). Home appliances and other devices designed for use with AC power will need to be run with an inverter, which will incur additional efficiency penalties.

How much power does stuff use?

Luckily, there are stickers or printed labels on most electronic products that say how much power they take to run. Sometimes it will be expressed in Amps and sometimes in Watts. That's okay, because the math is easy: Watts (W) = Volts (V) * Amps (I). (The I is from the archaic term Intensity of the current.)

AC loads

Let's say you are a minimalist and the only 110v appliances you take are a hot dog cooker and lava lamp.

  • Hot Dogger: 110v * 5A * 02.5hrs = 137.5Wh
  • lava lamp: 110v * 1A * 4hrs = 440Wh

Combined this would be 577.5Wh. But inverter losses apply to all 110v loads in your van, so multiply by 1.1: 440Wh * 1.1 = 484Wh

And since we are going to run it off a nominal 12v system we will divide by a typical "12v" voltage, which is usually stated as 13v. (12v system systems are basically discharged at 12v)

484Wh / 13 = 37.23Ah per day.

DC loads

DC appliances are usually labeled in Amps, so the math is easy.

  • Batman projector light: 2A * 1hr = 2Ah
  • Heated bunny slippers: 5A * 3hrs = 15Ah
  • Spinning disco ball: .5A * 3hrs = 1.5Ah

This is 18.5Ah per day.

Total loads

37.23A + 18.5A = 55.73Ah/day

For reasons explained below, this would require about 110Ah of battery capacity in your van.

Calculators

Also see the EU PVGIS modeler.

Your reserve needs

“ ...one that really [effed] with me was running out of power or spending a few days in the dark cause the weather is bad.[3]”

Your "solar harvest" (how much solar power you can get from the Sun each day) is highly dependent on local conditions like weather, season, and latitude. One cannot assume getting a full charge every day in every condition.

To account for this decide how many reserve days of power you need if there is little solar power available. solar power available. You may need few in desert regions and many more in the Pacific Northwest. Long stretches of little solar charging may necessitate rationing solar power.

It is safest and simplest for solar newbies to assume a day of poor solar harvest = zero solar harvest. In actuality zero harvest is highly unlikely; more experienced or risk-tolerant RVers can run with less reserve or no reserve at all.

Your battery bank

Now that we know the total amount of electrical capacity we need (from 24hr loads X number of days needed) it is time to figure out how that capacity is met by various battery chemistries.

It may not be obvious, but one cannot consistently use all the capacity in a battery without damaging it. Deep cycle batteries are usually cycled to 50% Depth of Discharge (DoD), so you will need a deep cycle bank 2x the size of your previously calculated needs. Starter batteries (those used to start your engine) may tolerate only 10% discharge. LiFePO4 batteries are happy to go down to about 90% discharged.

Example: You need 100AH x 1 day, so your bank will be 200AH cycled 50% each day.

Example:LiFePO4 can be drained down to 80%-90% DoD, so you would need only 110AH of rated capacity with that chemistry. 120AH if you are conservative.

A rule of thumb is flooded lead acid batteries in offgrid scenarios should be charged between C/10 and C/8. For a 200AH bank this would be 20A-25A. Charging at lesser rates may result in not getting fully charged each day. Charging at greater rates may result in increased outgassing and the need for a lengthier Absorption stage.

reserve

| total| 91| | | | | Minimum battery bank (except lithium) | 182|

and that's just to get through a 24hr period with good sun. If you want to get through a day (or more) of terrible solar yield (rain, snow, fog) it requires even more battery capacity (reserve), money, and cargo capacity. These numbers are both very rough but will illustrate the pattern:

| | Rated Ah | cost (flooded) | cost (AGM) | weight in lbs | | **Minimum battery bank (except lithium) 0 days of reserve**| 182| $182.00| $364.00| 91| | | | | | | | 1 day of reserve | 364| $364.00| $728.00| 182| | 2 days of reserve | 546| $546.00| $1,092.00| 273| | 3 days of reserve | 728| $728.00| $1,456.00| 364|

Charging efficiency

Lead batteries take something like ~13% more amps to charge from 50% DoD than were consumed. So if you need to replace 50A it will take ~56.5A the next day to replace it. While you are running your normal loads.

Lithium batteries have very high charging efficiency, so 50A consumed will take ~50A to recharge.

Voltage

Most camper solar installs run at nominal 12v. Because of this most accessories are 12v.

Some installations utilize 24v electrical systems. This is common in boats, and occasionally some very large commercial RVs. The common theme of an advantage to 24v is that you're using half the amperage to transfer the same amount of power, which can result in cheaper components

You may want to consider running a 24v system if:

  • You have a lot of solar, like 600w or more.
  • Ohm's law tells us that 600w / 12v = 50A but 600w / 24v = 25A. Therefor, you can use much smaller (and cheaper) wiring to connect your solar panels to the charge controller
  • You will be using inverters heavily
  • Inversion from 24vdc to 110vac is more efficient than inversion from 12vdc.
  • You have large, power-hungry appliances that can run natively off of 24v
  • Some DC refrigerators and induction cooktops can run off of both 12v or 24v, and are slightly more efficient when running off of 24v.
  • Off-grid air conditioning can be slightly more efficient with 24v native systems, and will allow smaller wires to be used.
  • You have a lot of long, large cable runs
  • 24v doesn't have as much voltage drop as 12v over a similar distance, and can use smaller/cheaper cables.
  • A 24v system can use a much smaller/cheaper charge controller

There are downsides to 24v, however. There are fewer 24v accessories, and you cannot use a chassis ground as it is already grounded to the coach's 12v system. It can also make alternator charging difficult, as DC-DC boost converters get quite expensive when they are sized to handle the required loads.

Solar panel array

Pick a solar panel array output on daily power requirements and battery bank capacity. A common rule of thumb for matching panels to battery bank is that at a minimum there should be 1 panel watt per amp-hour of nominal bank capacity.

“ ...the person draining their batteries to the 50% range regularly would do much better with a 2 watts to 1Ah ratio, or even 3 to 1.[4]”

Here are some examples using this model:

A crude rule of thumb for panel output per day is a horizontally mounted panel on a sunny day will generate Ah (amp hours) roughly equal to Rated Wattage / 3.[5] \\ Example: a 100W panel could output 33Ah/day.

Another rule of thumb for panel output per day is a horizontally mounted panel on a sunny day will generate Wh (Watt hours) roughly equal to Rated Wattage x 4.[6] \\ Example: a 100W panel could output 400Wh/day.

Charge controller

After the bank and panels have been sorted one must size the charge controller to the panels.

There are two general rules:

  • voltage from panels must not exceed controller voltage, ever.
  • controller rating should be the panels' output plus a safety margin, unless you are overpaneling an MPPT controller on purpose.

Augmenting solar

Solar power often works best when paired with another power source. This is because the first half and second half of smart charging have different time/power ramifications

  • high current / short duration during Bulk <-- generator, shore power converter and alternator charging do this best
  • low current / long duration once Absorption gets underway, and during Float <-- solar does this best

simple system

Joe Vandweller needs 50AH of power each day. He wants to get all of it from solar.

If he lives in the desert southwest he might need

  • 1 day of reserve, totaling 100AH of power
  • 200AH of lead acid (2p1s GC2 golf cart batteries) or 100AH of LiFePO4
  • 200W of panel
  • a 20A charge controller

if he lives in the Pacific northwest he might need

  • 3 days of reserve, totaling 200AH of power
  • 400AH of lead acid (2p2s) or 200AH of LiFePO4
  • 400W - 800W of panel
  • one or more 40A charge controllers

If Joe is willing to augment his solar with another charging source he can significantly reduce panel and charge controller requirements. The battery bank would stay the same; it just gets filled by more than one source.

maxxed system

In nomad solar configurations the order of sizing calculations may be different due to space or budget limitations. Few of us will be able to fit all the solar panels we need to run every load on our wishlist. In this case we size our systems for the maximum amount of panels we can fit in the space allowed. This might be what fits in open space on our roof, or how much portable panel we are willing to deploy.

  • max solar wattage you can install (or afford)
  • whether your have access to other forms of charging: shore power, alternator
  • max battery capacity you can charge fully/consistently (or afford, or install)
  • these factors will tell you what kind of loads you can run.

real solar installations

See the self-reported capabilities of real life configurations.


“ You have to build for winter, and figure out what to do with the extra electricity in summer.[7]”

power system sizing - the Big Picture

There are many calculators where you can plug in the numbers. This page is a 35,000ft view of how choices affect what you will need.

See this article for a sample walkthrough of the numbers.

overall economics

Since solar is dependent on local conditions one has to size the system to the worst conditions** the system is expected to experience: winter, high latitudes, bad weather. This means solar is relatively expensive when used alone where solar conditions are poor. Adding in another form of charging not affected by local conditions means you can downsize your solar to fit **average conditions, saving money and space.

In general, bigger systems (higher wattage panels, bigger controllers, bigger battery banks) cost less per-watt-harvested.

days of reserve

Your reserve requirements will profoundly affect the size, complexity, and cost of the system. Sizing for an overnight camping trip is easy; sizing for a three day trip a challenge; sizing for a long trip or full-time vandwelling is serious business. See the bottom of this article for example configurations.

battery bank

Once you know your daily power and reserve requirements you can spec out a battery bank. The capacity and chemistry of the bank will drive much of the charging section below.

Broadly speaking, lithium chemistries are most cost-effective when the camping experience is expected to last for many years and the batteries stored inside.((Note that it is false economy to pay for 10 years of battery cycling (as with lithium) if one is going to wreck it in 2 years)). For shorter projects (traveling around the country for ≤3 years) in an RV with exterior battery trays the standard T-105 style FLA bank[8] may be more cost-effective. For very short installations ( ≤1 year) marginal batteries found at walmart may be fine. I encourage people to do the $/kWh math for the situation rather than relying on the latest trends or loudest voices. Horses for courses.

Having an undersized bank means running out of power at night. Sitting in the dark at night with no fan.

Having an oversized lead bank** for your charging ability results in battery murder and replacement. Having an **oversized lithium bank is $$$ and can strain the alternator if a current-limiting isolator isn't used.

IMO, with lead chemistries[9] it is better to have an undersized bank you can charge fully and consistently rather than a bigger bank you cannot charge.

After figuring your rough capacity requirements, consider these factors:

You will need somewhat more Ah capacity

  • if you have undersized solar
  • you have lead-chemistry battery bank

You will need somewhat less Ah capacity

  • if you run loads in the daytime instead of at night
  • if you have oversized solar
  • you have lithium-chemistry battery bank((can be ~0.62% the size of the lead bank, due to deeper DoD.))

solar charging

solar panels

The absolute minimum for solar, assuming everything goes exactly right,[10] is often said to be 1:1 panel-to-Ah. e.g. 150w for a 150Ah battery bank. In reality, solar that small is often insufficient unless one has unusually small power needs or adds in another form of charging (see below). Newbies typically think their power needs are small until they sit down to read those power labels on the stuff that want to run. D'oh!

Most people will do best with much more panel-to-battery depending on battery chemistry, geography and use patterns.

You will need somewhat more solar

  • if you live in an area with relatively little sun, like the American Northwest.
  • if you want to run more loads
  • if you live offgrid full time (FT) or spend long periods boondocking
  • to run things off inverter rather than 12v((due to inversion losses, typically at least 10%))
  • to charge a bigger battery bank
  • to charge lead-chemistry (FLA, AGM, Gel) banks

You will need somewhat less solar

  • if you live in an area with a great deal of sun, like the American Southwest.
  • if you camp recreationally mainly in the summer when solar harvest is easier
  • if you augment solar with generator, isolator, shore power etc
  • if you live in the vehicle part time (PT) and can charge consistently from shore power when not camping.
  • if you voluntarily reduce your power consumption
  • if you time-shift loads to periods like the afternoon when excess power is available
  • to charge lithium banks

calculating real numbers

Accurate calculations would involve:

  • the Ah/Wh to be replaced
  • the charging efficiency of the battery chemistry (We might ballpark, 99% for Lithium, 80% for FLA, and 90% for AGM.
  • overall efficiency of the solar setup (we can ballpark 85% for MPPT setups, 70% for PWM)
  • average insolation sun power available at the time/place; in the northern hemisphere full-timers base this on December since it's the lowest-yield month. For part-timers, it will be the month of lowest insolation you will camp in.
  • minimum charging current requirements, if solar is the sole charging source (we can ballpark 0.2C for AGM and 0.1C for FLA)

Let's assume a 200Ah AGM bank depleted to 50% SoC, wintering in Quartzsite with an MPPT-based solar config and flat-mounted panels.

  • 200Ah x 50% = 100Ah to be replaced
  • converting to Wh, 100Ah x nominal 12v = 1200Wh to be replaced
  • battery charging efficiency of 90% means we need 1333.33Wh of actual charging power to replace the 1200Wh (1200Wh / 0.90)
  • the solar install operates at a 85% efficiency, so we need 1568.63Wh of harvestable sun power landing on the panels (1333.33Wh / 0.85)
  • In December in Quartzsite, a panel will receive an daily average of 3.08 hours of full sun equivalent
  • So we need 590W of panel (1568.63Wh / 3.08 hours)

In practice you probably won't be drawing your bank to the lowest allowed level each day; substitute your actual daily power requirements. You may find it easier in the long-term to model this kind of thing in a spreadsheet.

Note: the numbers are for average yields, including average seasonal weather. Individual days may be better or worse. If you have non-negotiable power requirements you may want to oversize your array to account for days of locally-poor harvest.

solar charge controller

controller choice

The controller's job is to sit in between the panels and battery bank and regulate charging. Counterintuitively, its most important job is to prevent overcharging.

Most people do fine with a PWM controller. Folks who live off-grid with lead-chemistry batteries can get by with even a $10 cheapie. Nicer PWM have staged ("smart") charging, more configurabilty, and likely better reliability.

You may want an MPPT controller:

  • if you discharge your batteries deeply overnight[11]
  • if you have a lithium or AGM bank((they have lower resistance and so come up to voltage more slowly; see point above))

You will need an MPPT controller:

  • if your panels are higher voltage than your battery bank (e.g. 24v panels and 12v bank)

controller sizing

Controllers are rated by the Amps they can pump out. A 20A controller can handle up to 20 Amps (about 250w incoming power, depending on battery voltage).

A common rule of thumb for sizing PWM controllers is to divide panel wattage by 10; 300w[12] of panel on a 30A PWM controller. They are cheap enough that a little oversizing is not a big deal, and they need a bit of headroom since they do not throttle incoming current to protect themselves.[13] See these examples.

MPPT sizing is less straightforward. These tend to cost 2-3x as much for a given rating as PWM, so oversizing can get $$$. MPPT have the ability to clip power during unusually-high harvest to limit current to their rated capacity. For this reason they are often sized to the power the panels make under normal circumstances rather than the panels' lab rated power.

Examples:

  • A 200w panel might really only make 166W in actual use under good conditions. This panel might be used with a 15A MPPT controller.
  • 300w of panel might make 249w under good conditions. 25A controllers are rare, so they might be put on a 20A mppt controller
  • MPPT smaller than 10A are rare, so 100w-150w of panel are usually put on 10A mppt.
  • more examples with explanation

alternator charging

For many people living in vehicles alternator charging + modest solar will be the best-performing system for the dollar. The ratio of camping vs driving[14] will affect the solar/isolator/generator balance.

You will need some kind of alternator charging

  • if you have no solar
  • if you have insufficient solar <-- very common
  • if you have AGM, which craves a ton of current in Bulk charging

You will not need alternator charging

  • if you have a ton of solar
  • if you stay on shore power much of the time
  • if have solar and most of your driving happens after noon[15]

More expensive DC-DC chargers are warranted when

  • you have no solar
  • current-hungry battery like AGM or lithium threatens your alternator's longevity, or you need to restrict charging rate for lithium.
  • you have a voltage-sensitive battery like gel or lithium

generator charging

You may need a generator if:

special case: trailers

Cargo trailers[16] have unique advantages and disadvantages

advantages

  • flat roof space for panels, especially cheaper-by-the-watt large panels
  • relatively low, making tiltable arrays more practical since you can reach them

disadvantages

  • charging from alternator can be challenging. See one way around the charging limitations of the 7-pin harness.

RV travel trailers have additional challenges

  • roofspace often lacks contiguous open spots to mount panels
  • rooftop accessories shade panels
  • large parasitic loads, due to the common assumption they will be hooked up to a power pedestal at a paid campsite

example setups

overnight camping

  • advantages - only 24 hours away from home (and grid power), only need to store power for 24 hours of use. No need to generate power.
  • challenges - need to keep battery bank on a small charger/maintainer at home to avoid sulfation and early death

The battery is used occasionally and briefly then put back on the maintainer at home. The battery doesn't have to be particularly good[17]; it can be a chain store battery, often labeled "marine" or "hybrid" or similar.

It is used to run small fans, LED lights, recharge phones.

weekend camping

This is like the scenario above, only with more battery capacity required.

For a longer discussion Also see blog article AGM Charging for Weekenders.

overlanding

In this scenario you are away from home for long stretches of time, driving daily to the next campsite. The system needs to be self-sufficient

  • advantages - driving daily makes DC-DC chargers highly effective.
  • disadvantages - rough roads increase likelihood of damage to flooded lead batteries. Forest camping can make shade a challenge. Fully-provisioned roof racks make mounted solar a challenge.

More expensive chemistries like AGM or lithium are warranted; plain FLA batteries may experience plate damage from vibration and rough driving. DC-DC charging will do the majority of charging, with a portable panel or two supplementing charging/loads during the day.

stealth camping

Stealth camping has some similarity to overlanding in that the stealth camper will likely drive every day.

  • advantages - driving at least a short distance every day for relocation or work commute makes alternator charging effective.
  • disadvantages - need to remain stealthy limits solar array mounting

The relatively short distances driven by stealthers means that a plain isolator will likely outperform a fancy DC-DC charger. These quick blasts suggest the need for a bank that can suck up power fast: AGM or lithium.

The need for stealth suggests smaller (or just more discreet) arrays): higher-efficiency panels, perhaps with black frames to minimize visual impact to onlookers. Mounting on OEM racks can help fool the eye.

The possibility of shore power charging, even rarely, means the stealther may want to adding a shore power port and converter/charger.((and carry a long, heavy, outdoor-rated extension cord!))

fulltime boondocking

  • advantages - roofspace can be devoted to large solar arrays. Can choose batteries based on long-term value.
  • disadvantages - in-place camping makes DC-DC charging less cost-effective. Entire life must be powered, not just recreational loads while camping. Days of autonomy == forever.

FT boondocking game or vacation anymore; this is your life. You need power every day and under all conditions. The most reliable way to do this is by overpaneling (having massive solar to account for all weather conditions), although you could do it with smaller solar combined with a generator.

Battery banks tend to be either lithium or flooded 6v golf cart[19] batteries in series, both of which have lifetime $/kAh costs under $2.


How much extra solar power do I have?

Yes, we can use a battery monitor to see how much power is going into the battery bank. And we can look at the solar charge controller to see how much power it is making.

But how can we tell how much untapped power does our solar have in reserve? Put another way: how much more stuff could we be running off the solar?

TLDR

  • it is easy to test whether or not you can run a specific load
  • it takes a lot of "seat time" with the system to predict how much excess power you have at a given moment
  • it requires some math to predict whether or not you can run a load on average at a given place/time

about these summaries

direct testing

Plug it in and see if the solar can support it without affecting the battery bank. Easy peasy.

The downside is this is a YES/NO answer; it tells you a specific load will run but does not tell you about how much power is actually available. If you want to see the Bigger Picture then read on...

prediction

looking up daily insolation (FSE) =

Hours of Full Sun Equivalent (FSE) is a convenient way to think of the amount of sunlight reaching the ground over the entire day. 4.5 hours of FSE means 4.5kWh of power reaching the ground per square meter.

To predict daily harvest we will use

  • FSE
  • your panel wattage
  • and your system's overall efficiency

calculating power available (W)

Real-time harvest is a bit easier since there is no time component. We are working in Watts (W) rather than Watt-hours (Wh). What we are doing is comparing the strength of sunlight reaching the ground (perpendicular) vs the cosine of the angle at which it actually strikes the ground, or strikes a flat-mounted panel.

This cosine is calculable for a given time and place.

Example**: if you have 200w of panels and calculated cosine is .70 then **140w of direct light is landing on your panels in clear skies.

finding and using system efficiency

For various reasons your solar setup will not be able to harvest all the power landing on the panels. For systems with PWM controllers the percent harvested will be something like 70%. For MPPT it might be 83%. These constants will be placeholders you can use until you figure out your specific system's overall efficiency.

You can see our system's overall efficiency at a given time: actual harvest / theoretical harvest. The numbers will jump around but over time you will start to see a pattern. Maybe yours makes 80% or 86% over time. Use that number to predict how your system will behave in another time/place:

  panel wattage x system efficiency x cosine

>> ...if your mppt controller typically yields 83% after derating, and the calculated cosine is .70 then you might expect ~116w in clear conditions at that time in that location. (200 x .83 x .7 = 116.2).


Words of Wisdom: "I'm not sure people always grasp the concept of "minimum" either; they tend to think it means "all that you really need" when it fact it means "the least you can get away with provided everything else goes right". After all, the sun does not shine brightly every day." -- Cariboocoot[20]

Solar panel sizing for different geographical areas

This page is a rough attempt to show how geographical location and meteorological conditions affect the amount of solar wattage one needs.

Reminder:** available sunlight (insolation) is expressed in Hours of **Full Sun Equivalent (FSE)** compared to lab conditions. So an entire cloudy day might provide only 2 hours of FSE, meaning it would be the same amount of sunlight as 2 hours of full sunlight under lab conditions (1000w/sq meter). Therefore **2 hours of FSE = 2kWh.((and 7.2MJ (megajoules) for our metric friends)) Multiply [FSE for the time/place] x [rated panel wattage] to see what see how many watts your system would harvest on average if it were perfectly efficient.((hint: it's not)). Example: 4 hours of FSE x 200w = 800Wh, or 0.8kWh, before various losses.[21]

Historical weather info is also used to calculate FSE, so good/bad weather is already baked into the average.

representative areas

These locations represent the least, average, and most sunlight available in the Continental US. The data is taken from this table.

Worst/lowest FSE tends to occur in December, and most/highest FSE in July.

^ Location ^ Average FSE ^ Worst FSE ^ Best FSE | | Seattle, WA | 3.53 | 0.90 | 6.27 | | Salt Lake City, UT | 4.53 | 1.97 | 6.98 | | Phoenix, AZ | 5.38 | 2.75 | 7.7 |

Note that during periods of poor insolation Phoenix has over 3x the sunlight as Seattle. In summer though, it only has 1.2x as much sunlight:

> "The difference in bright sunlight between the least efficient and the most is little. What a panel does in cloudy conditions can make or break your system." -- jimindenver[22]

Amount of solar wattage required per 100Ah of Pb

These are crude estimates about the panel wattage required to fully charge 100Ah of AGM from 50% DoD each day. See the list of assumptions below the chart.

^ Location ^ MPPT only ^ PWM only ^ w/ isolator ^ w/ DC-DC charger or generator ^ | Seattle - avg | 280w | 329w | 140w | 103w | | Seattle - Dec | 921w | 1056w | 528w | 388w | | Seattle - Jul | 163w | 192w | 82w | 60w | | | | | | | | SLC - avg | 238w | 281w | 119w | 88w | | SLC - Dec | 473w | 556w | 236w | 174w | | SLC - Jul | 156w | 183w | 78w | 57w | | | | | | | | Phoenix - avg | 200w | 235w | 100w | 73w | | Phoenix - Dec | 369w | 434w | 184w | 135w | | Phoenix - Jul | 149w | 175w | 74w | 55w |

Assumptions:

  • panel output is temperature-derated according to daily average high at each time/place
  • no other loads other than charging are present
  • AGM deep cycle battery is discharged to 50% DoD nightly and fully charged the next day. Charging efficiency 90%.
  • MPPT controller is 95% efficient
  • PWM yields, overall, 85% of MPPT yield. PWM yields will be quite close to MPPT yields when other forms of charging is present, as PWM will no longer be hamstrung by low Vbatt.
  • isolator charging is done in early morning, every morning, at ~C/3((~33A, AGM max charging current)), and discontinued when alternator no longer raises voltage.((~14.4v?)) The chart assumes at that point ~50% of charging will be done.
  • DC-DC (or generator) charging is is done in early morning every morning, at C/3,((~33A, AGM max charging current)) and discontinued when Vabs is achieved[23]. We assume at this point 63.3%% of charging will be done. The practical difference between alternator charging and DC-DC or generator charging is the latter will charge all the way to Absorption voltage.
  • temperature-related derating baked in based on monthly average high temperatures
  • due to lower internal resistance lithium will accept more charge from alternator/generator than AGM by the time it reaches the charging source's voltage setpoint, thereby requiring somewhat less panel wattage. Likewise, flooded batteries will accept less than AGM and then require more panel.
  • solar-only charging the same number of amps into lithium would require about 10% less panel than AGM due to better charging efficiency. Lithium can be charged successfully off alternator/generator only so no panel would be required.


DIY Solar Power Forum
A very active solar forum with 100k members, founded by Will Prowse. Lots of residential and commercial solar discussion, but the "Vehicle Mounted Systems" sub-forum has plenty of info specific for nomads. Other sub-forums for batteries and solar equipment.

Quick Search

Search for “solar system sizing” on:

  1. van life discussion groups,
  2. van life web sites, or
  3. other pages on this wiki

Wiki Tools

A user account is required for these options:

Credit

Some content on this page was originally sourced from doku.php?id=electrical/solar:sizing on RVWiki.

Table of Contents

  1. Jump to top ⤒
  2. 1 – Your daily power needs
  3. 1.1 – How much power does stuff use?
  4. 1.2 – AC loads
  5. 1.3 – DC loads
  6. 1.4 – Total loads
  7. 1.5 – Calculators
  8. 2 – Your reserve needs
  9. 3 – Your battery bank
  10. 3.1 – reserve
  11. 3.2 – Charging efficiency
  12. 3.3 – Voltage
  13. 4 – Solar panel array
  14. 5 – Charge controller
  15. 6 – Augmenting solar
  16. 7 – simple system
  17. 8 – maxxed system
  18. 9 – real solar installations
  19. 10 – power system sizing - the Big Picture
  20. 11 – overall economics
  21. 11.1 – days of reserve
  22. 12 – battery bank
  23. 13 – solar charging
  24. 13.1 – solar panels
  25. 13.2 – calculating real numbers
  26. 13.3 – solar charge controller
  27. 13.4 – controller choice
  28. 13.5 – controller sizing
  29. 14 – alternator charging
  30. 15 – generator charging
  31. 16 – special case: trailers
  32. 17 – example setups
  33. 17.1 – overnight camping
  34. 17.2 – weekend camping
  35. 17.3 – overlanding
  36. 17.4 – stealth camping
  37. 17.5 – fulltime boondocking
  38. 18 – How much extra solar power do I have?
  39. 19 – TLDR
  40. 20 – direct testing
  41. 21 – prediction
  42. 21.1 – looking up daily insolation (FSE) =
  43. 21.2 – calculating power available (W)
  44. 21.3 – finding and using system efficiency
  45. 22 – Solar panel sizing for different geographical areas
  46. 23 – representative areas
  47. 24 – Amount of solar wattage required per 100Ah of Pb
  48. Resources
  49. External Links (1) 🔗
  50. Wiki Tools
  51. Jump to Footer ⤓

Nomad Life Wiki